The Medacta Shoulder System is a modular solution that features a broad range of options, including wide-ranging sizes, adjustable offset and innovative configurations both in the anatomic and in the reverse configuration.

The Medacta Shoulder System provides 2 stem options, standard and short, 3 humeral inclination options for TSA (128 º /135 º /142º) and 2 for RSA (145° and 155°), 4 sizes for RSA glenosphere and 10 cemented pegged glenoid for TSA for an optimized mismatch.

The Medacta Shoulder System offers the flexibility to move from a total to a reverse arthroplasty, without the need to revise all components. The aim is to have conversions rather than revisions of the all prosthesis components.

Composed of innovative components, the design of which has been based on the most recent research in shoulder replacement the system is compatible with, and can be further enhanced by, the CT-based MyShoulder 3D preoperative planning solution, offering patient-specific humeral and glenoid guides.

Interested?

Talk to one of our Shoulder Specialists

CONTACT US

Humeral Stability

The humeral diaphysis has a self-centering and self-orienting shape. The calcar design has been optimised, through extensive trialing using 3D imaging and cadaver analysis, and delivers enhanced primary stability. Achieving a precise fit between stem and humeral canal is made possible with the extensive size range available with this system.

Reverse Configuration Improvements

With an innovative design of the liner, the surgeon has the opportunity to adapt the system to the patient’s conditions by potentially increasing joint ROM (145° humeral inclination) and maximizing joint stability (155° humeral inclination). The glenosphere has a lateral offset (4 mm) and also an inferior offset (2 mm) to reduce the risk of scapular notching. The complete hemispherical design delivers stability through full ROM.

Anatomic Configuration Improvements

The surgeon has the opportunity to ideally match and reproduce the head-stem offset using the double eccenter-head. This option delivers an adjustable head eccentricity between 0 and 5 mm. The Medacta Shoulder System provides 3 anatomical metaphysis inclination options (128° / 135° / 142°) to match the pre-operative humeral inclination.

Ideal Platform for conversion from TSA to RSA

In case of revision, the humeral diaphysis remains in place and is used to receive the reverse metaphysis and the reverse liner. This is a less invasive revision surgery option but continues to deliver satisfactory stability of the prosthesis.

Anatomic

Humeral Diaphysis

Standard and Short versions


11 sizes for each version


Cementless (Ti-Plasma spray + HA) and cemented (only for Standard Stem) options

Humeral Anatomic Metaphysis

3 inclination options: 128 º /135 º /142º


Cementless (Ti-Plasma spray + HA) and cemented options


Suture Sleeves: Ø2.5mm

Double Eccenter

Adjustable head eccentricity (0 ÷ 5 mm)

Humeral Head

10 sizes


Material: CoCrMo – ISO 5832-12 (ASTM F1537)

Cemented Glenoid

10 sizes


Material: Highly cross-linked polyethylene

Reverse

Humeral Diaphysis

Standard and Short versions


11 sizes for each version


Cementless (Ti-Plasma spray + HA) and cemented (only for Standard Stem) options

Humeral Reverse Metaphysis

Two height options: +0 and +9 mm


Two version options: +/- 20º


Material: Ti6Al4V – ISO 5832-3 (ASTM F136)


Inlay design with HA


Suture Sleeves: Ø2 mm

Humeral Reverse HC Liner

Three height options: +0 / +3 / +6 mm


Inclination options: 145° and 155°


Material: Highly cross-linked polyethylene

Pegged Glenoid Baseplate

Three diameter options: 22, 24.5 and 27 mm


Three peg length options: 15, 25 and 35 mm


Material: Ti6Al4V – ISO 5832-3 (ASTM F136) with HA (Grit blasted front surface)

Threaded Glenoid Baseplate

Two diameter options: 24.5 and 27 mm


Three peg length options: 25, 30 and 35 mm


Material: Ti6Al4V – ISO 5832-3 (ASTM F136) + Type II anodization with 300μm Mectagrip

Glenosphere

Four diameter options: 32, 36, 39 and 42 mm


Lateralized COR: 4mm


Embedded Inferior offset: 2mm


Material: CoCrMo – ISO 5832-12 (ASTM F1537)

Glenoid Polyaxial Locking Screw

10 sizes


± 15° of angulation


Material: Outer screw: Ti6Al4V – ISO 5832-3 (ASTM F136) + Type II anodization. Inner screw: CoCrMo – ISO 5832-12 (ASTM F1537)

Glenoid Polyaxial Non-Locking Screw

10 sizes


± 15° of angulation


Material: Ti6Al4V – ISO 5832-3 (ASTM F136) + Type II anodization

LEARN MORE ABOUT MEDACTA SHOULDER SYSTEM

Medacta’s core philosophy is based on the belief that innovation is the key to success and the company consistently strives to develop and deliver cutting edge solutions for Orthopaedics. The MyShoulder system is one of these solutions, allowing a surgeon to realise the pre-operative 3D planning and deliver accurate implant placement using CT based 3D printed cutting and pin guides. This innovative product delivers benefits to both the surgeon and to the patient. MyShoulder consists of 3D pre-operative planning and patient-specific guides, and has been developed following the success of Medacta Patient Matched Technology.

Why choose MyShoulder?

  • Accurate implant positioning and sizing
  • Complete 3D preoperative planning
  • Complete in-house technology: the MyShoulder process is performed entirely by Medacta
  • A personal MyShoulder technician
  • Only 3 weeks lead time

MyShoulder Workflow

CT Images

Medacta receives the CT images of the patient‘s shoulder.

3D Reconstruction

Starting from the 3D reconstruction of the joint and following the surgeon preferences, the MyShoulder preoperative planning is performed.

Virtual Positioning

A virtual positioning of the implants is proposed, with the ability for the surgeon to modify the planning as required.

In-house Manufacturing

Once the surgeon has validated the planning, the in-house manufacturing process starts.

LEARN MORE ABOUT MYSHOULDER SYSTEM
CLICK TO VIEW CLINICAL REFERENCES

CONTACT US TODAY